    • Continuous Emission Monitoring
    • -40 to +50 Celsius (oC)
    • 230 VAC
    • 30 Kilograms (kg)
    • Automatic
    Product Description

    Online Continuous Emissions Monitoring Systems (OCEMS) Model ATS-208A

    Approved by TUV

    As per latest CPCB guidelines, it is now mandatory to monitor online continuous S Emission Monitoring Systems (OCEMS) in 17 categories of highly polluting industries and in Common Hazardous waste and Biomedical waste incinerators for the parameters(industry/sector specific parameter) mentioned in the consent to operate/authorisation not later than by JUNE 30,2015.

    We offer comprehensive range of stack gas Analyzer Continuous for the analysis of stack/flue gases in exhaust, boiler and combustion process.

    Continuous Monitoring of‚  SO2, NOX (NO NO2), SPM, H2, H2S, N2, CO2 ,CH4, CO, O2,

    Duel wavelength Infra red sensor for Long terms accuracy and stability

    Long Life Electrochemical sensor

    Six Gas Analysis in Single Analyser

    Multi Parameter Single 320 X 240 Graphics LCD Display

    Self diagnostic & Self integrity check

    RS 232/RS 485 and USB Computer Interface

    Excellent low level capability for NOX and SO2 Measurement

    For most of the application sample gas is cooled and dried inside the sampling conditioning systems to avoid the Heated Sample Line.

    Analog 4-20mA output for each gas

    Online Continuous Emission Monitoring Systems (OCEMS) Model ATS- 208A Emission Analyzer continuously monitors the concentration of gases ranging from 100%V/V down to PPM level. Feature includes a duel wavelength sensor, Remote Sampling, Graphics LCD Display, adjustable level relay output for alarm and 4-20mA output for control purpose and minimal maintenance.

    Special gas sample Conditioning systems are used to clean and dry the gas sample for accurate and High performance operation. An Internal Pump draw gas sample into the sensor through a dust particle filter from an intake which can be located at distance up to 40 meter form the monitor.

    The Sensor and Electronic component are housed in tough aluminium housing

    Specifications:

    Principle: Electrochemical, TCD (Thermal Conductivity) , NDIR (Non Dispersive Infrared ), Zirconium and Paramagnetic

    Range: %V/V, % LEL, PPM, Mg/M3

    Resolution: 0.1 Unit or 1 Unit (Application based)

    Sampling Method: Auto Suction

    Display: 320 X 264 Graphic LCD

    Alarm; Relay Contact NO NC

    Analog Out Put: 4-20mA

    Digital Out Put : RS 232, RS 485 and Modbus Communication Protocol

    Power Source: 230VAC

    Accuracy: /2%

    Response Time: <5 Second

    Sensor Life: 2-3 Years

    Environmental:

    Temperature:-15degree Celsius Humidity :< 85%RH Atmosphere Pressure: 86- 106Kpa

    Dimension in mm: 430 (W) X 150(H) X 250(D)

    Weight: 2.5 KG

    Warranty: One Year

    Trade Information
    • Telegraphic Transfer (T/T), Cheque, Cash on Delivery (COD)
    • 30 Per Month
    • 2-3 Week
    • Free samples are available
    • Normal Box
    • Africa, Middle East, Western Europe, Eastern Europe, South America, North America, Central America, Australia, Asia
    • All India
    • TUV, IS0 9001:2015
      Contact Us

      104, Delta Industrial Estate, Building No 1, Gokhivare,Sativali Road, Vasai East, Dist-Palghar Vasai Maharashtra India